OEM Siemens POWER ELECTRONICS DVIVCES
Product
code |
Input
voltage |
Rated
power
kVA/kW |
Output |
Output
protection |
CONV A60 |
400V 3Ph, 50Hz |
60kVA/54kW |
440V 3Ph+N, 60Hz |
Switch isolator |
CONV A20 |
380V 3Ph, 50Hz |
20kVA/18kW |
115V 3Ph, 400Hz |
Switch isolator |
Product
code |
Input
voltage |
Rated
power |
Output |
Output
protection |
INV 160-330 20 60Hz |
160Vdc �?330Vdc (max 450Vdc 50msec) |
20kVA/16kW |
115V 1Ph+N, 60Hz |
Contactor |
INV 160-330 20 400Hz |
160Vdc �?330Vdc (max 450Vdc 50msec) |
20kVA/16kW |
115V 3Ph+N, 400Hz |
Contactor | STATIC FREQUENCY CONVERTERS 400 Hz FEATURES: �?High efficiency > 93%; �?Filtered, stabilized and regulated sine wave supply; �?400Hz ± 0.01% frequency accuracy; �?Input power factor > 0.95; �?Wide input voltage and frequency range �?Insulation transformer; �?LCD display; �?Emergency Power Off; �?Power up to 315 kVA STANDARDS: �?ISO 6858 �?MIL‐STD�?04 �?EN 2282 FIELDS OF APPLICATION �?AVIATION �?MARINE �?MILITARY �?INDUSTRY �?OIL & GAS FEATURES �?High efficiency > 93%; �?Filtered, stabilized and regulated sine wave supply; �?Input power factor > 0.95; �?Wide input voltage and frequency range �?Insulation transformer; �?LCD display; �?Emergency Power Off; �?Power up to 800 kVA STATIC FREQUENCY CONVERTERS 50Hz-60Hz STANDARDS: �?ISO 6858 �?MIL‐STD�?04 �?EN 2282 LUMINOUS FLUX REGULATORS FIELDS OF APPLICATION �?AIRPORT ILLUMINATION �?INDUTRIAL PLANTS �?PUBLIC LIGHTING �?BORDER SECURITY FEATURES: �?Input power factor at full load > 0.95; �?Efficiency > 90%; �?Energy saving with reduction of luminous flux; �?Reduced cable cross section of plant system (9.6A or 20A): up to 100kVA; �?Absence of any stress on electrodes lamp during ignition; �?Certificated Insulation controller; �?1% output current stabilization. STANDARDS: �?EN 60662 �?CEI 64�? �?EN 60071�?/2 (CEI 28�?) �?EN 50081�? �?EN 50082�? FREQUENCY CONVERTERS FOR VESSELS POSSIBLE CONFIGURATIONS: �?on the dock �?DOCK SERIES. Predefined Input Voltage (dock) to selectable Output Frequency/Voltage (vessel). �?onboard �?NAVY SERIES. Selectable Input Frequency/Voltage (dock) to Predefined Output Voltage (vessel). STANDARDS: �?EN 62040 �?EN 60950 �?EN 61000 FREQUENCY CONVERTERS FOR VESSELS FEATURES: �?High efficiency > 93% �?Filtered, stabilized and regulated sine wave supply; �?High input power factor; �?Automatic working; �?LCD display; �?Insulation transformer; �?Remote control as option; �?Drop line compensation as option; �?Battery version (UPS) as option; �?IP55 as option; �?Mobile or horizontal version as option; �?Low audible noise; �?Dry contact interface standard , RS232, USB, RS485 and SNMP as option; �?Emergency Power Off. MAIN APPLICATIONS: �?AUTOMATION �?INDUTRIAL PLANTS �?OIL & GAS �?RAILWAYS AND TRAINS �?TELECOMMUNICATIONS �?CIVIL AND MILITARY AVIATION �?NAVY �?PHOTOVOLTAIC PLANTS (OFF GRID) �?COMMERCIAL AND LEISURE VESSELS INVERTERS 110 Vdc �?220 Vdc input INVERTERS 110 Vdc �?220 Vdc input FEATURES: �?Input filter �?IGBT conversion unit (Inverter) �?Output filter �?Output insulation transformer �?Static switch as option �?Manual by‐pass as option �?Insulation transformer for emergency line (as option) �?Parallel kit feature (as option) STANDARDS: �?EN 62040 �?EN 60950 �?EN 61000 Inverter transforms the continuous voltage into an alternating sinusoidal stabilized voltage. The PWM modulation technique used reduces the harmonic content of the output and limits voltage deviations under step load conditions. MAIN APPLICATIONS: �?UTILITY & COMMUNICATION �?POWER GENERATION �?SUBSTATIONS �?MICROWAVE RELAY SITES �?SWITCHGEARS �?MANUFACTURING �?EMERGENCY DC POWER �?DC BRAKERS �?COMMERCIAL �?ALARM SYSTEMS �?DC CONTROL SYSTEMS �?TRANSPORTATION (Marine �?Aviation) �?SIGNAL SYSTEMS �?ALARM SYSTEMS �?BATTERY CHARGERS RECTIFIER / Battery Chargers RECTIFIER / Battery Chargers FEATURES: • Clean and stable output DC current with ripple voltage peak‐peak value <1% • Redundant fan system with temperature and air flow control. • Automatic charging modes. • Manual charging mode. • Adjustable voltage levels (the rectifier can operate as a power supply at the rated voltage or as a battery charger). • Adjustable times and alarm thresholds. • Temperature compensation • Digital microprocessor control (DSP + PLD). • Full optical isolation on all the logic and interface cards. • Low input harmonic distortion with the 12/18/24�?BR>phase bridge and the optional input filter. • Certified to withstand the harshest environment conditions. • Efficiency exceeding 90% (low‐frequency transformer included). • Modbus communication interface through RS232 or RS485 port. • Ethernet connectivity. • Battery monitoring system. • “H class�?input isolation transformer. UPS �?UNINTERRUPTIBLE POWER SUPPLY Single Phase Single phase UPS of many size to cover multiple purposes. Typical applications range from distributed PLC based controls to complete Distributed Control Systems (DCS) with power requirements ranging from 3 to 50 KVA�?50/60Hz. UPS �?UNINTERRUPTIBLE POWER SUPPLY Three Phase Three phase power back‐up and power quality solutions for mission critical applications in refineries, petrochemicals, power generation, steel & metals, process industries, healthcare, telecommunications as well as airport power applications. UPS range from 20kVA to 800KVA.
|
|
|
|